Insulation is rated in R-value per inch, and the total R of a cavity is that rate times the thickness. This calculator gives the R-value of a thickness you have, or the thickness needed for the R-value you want, for batts, blown-in, rigid foam and spray foam using the U.S. Department of Energy figures. Then it counts the packages for your area from the coverage printed on the bag.
Insulation R-value calculator
How it works
- R-value = R per inch × thickness; thickness = target R ÷ R per inch
- R per inch (DOE): fiberglass batt 3.1, blown fiberglass 2.2 to 2.8, mineral wool 3.1 to 3.2, cellulose 3.7, EPS board 4.0, XPS 5.0, polyiso 6.0, open-cell spray foam 3.5, closed-cell 6.2
- Packages = area × (1 + waste) ÷ coverage per package, rounded up
- RSI (metric) = R × 0.176
Worked example
Standard 3-1/2 in fiberglass batts in 2×4 walls, 1,000 sq ft of wall, 40 sq ft per bag:
- Insulation: Fiberglass batt (R-3.1 per in)
- R-value per inch: 3.1
- I know the: Thickness, and want the R-value
- Thickness: 3.5 in
- Area to insulate: 1000 sq ft
- Coverage per package: 40 sq ft
- Waste: 5%
The calculator gives:
- R-value: R-10.9 (RSI 1.91) at 3.5 in
- Packages: 27 at 40 sq ft each, with 5% waste
- Area: 1,000 sq ft (92.9 m²)
- Rate used: R-3.1 per inch
R-10.9 nominal (sold as R-11 or, in a denser batt, R-13) and 27 bags with 5% waste. To reach R-38 in an attic with blown cellulose at R-3.7 per inch you need about 10-1/4 in of depth; the bag lists how many square feet it covers at that depth.
Material and waste notes
- DOE recommends roughly R-13 to R-21 for walls and R-30 to R-60 for attics depending on climate zone; the local energy code sets the minimum.
- Compressing a batt into a shallower cavity lowers its R-value. Match the batt to the framing depth.
- Framing takes about 15 to 25% of a wall’s area and insulates far worse than the cavity, so the whole-wall R is lower than the cavity R.
- Blown products list coverage per bag at each depth; use that figure for the package coverage.
- Vapour retarders, air sealing and ventilation matter as much as the R number; foam board and closed-cell foam also act as vapour retarders.
Frequently asked questions
What is the R-value of 3.5 inches of fiberglass?
About R-11 at 3.1 per inch; high-density 3-1/2 in batts are rated R-13 to R-15.
How many inches of blown insulation for R-38?
About 10 to 10-1/2 in of cellulose (R-3.7 per inch) or 13 to 14 in of blown fiberglass. Bags state the settled depth for R-38.
How many batts are in a bag?
Typically 8 to 16 batts, covering 40 to 90 sq ft depending on width, length and thickness. The coverage is on the label.
Which insulation has the highest R-value per inch?
Closed-cell spray foam and polyiso board, around R-6 per inch, followed by XPS at R-5. Fiberglass and mineral wool are about R-3.1 to 3.2.
What R-value should attic insulation be?
R-30 in the warmest zones up to R-49 or R-60 in cold climates. Add to existing insulation rather than replacing it.
Sources
Last reviewed: 26 September 2026. The calculation is covered by automated tests with known answers taken from the sources above. Found an error? Please let us know.
More drywall, paint, tile & interior finishes calculators
- Joint Compound Calculator (Drywall Mud & Tape)
- Siding Calculator (Squares of Siding)
- Baseboard & Trim Calculator (Linear Feet and Pieces)
- Tile Calculator (Tiles, Boxes, Grout and Thinset)
- Flooring Calculator (Square Feet, Waste, Boxes and Cost)
- Drywall Calculator (Sheets, Screws, Mud and Tape)
- Paint Calculator (Gallons for Walls and Ceilings)
- Wallpaper Calculator (Rolls Needed with Pattern Repeat)
- All 50 construction and woodworking calculators